Giwa, S. B.
Department of Chemical Engineering, Faculty of Engineering and Technology, Ladoke Akintola University of Technology (LAUTECH), Ogbomoso, Nigeria
Aremu, J. B.
Department of Chemical Engineering, Faculty of Engineering and Technology, Ladoke Akintola University of Technology (LAUTECH), Ogbomoso, Nigeria
Araromi, D. O.
Department of Chemical Engineering, Faculty of Engineering and Technology, Ladoke Akintola University of Technology (LAUTECH), Ogbomoso, Nigeria
Sulayman, A. A.
Department of Chemical Engineering, Faculty of Engineering and Technology, Ladoke Akintola University of Technology (LAUTECH), Ogbomoso, Nigeria
ABSTRACT
Proton Exchange Membrane Fuel Cells (PEMFCs) are
attractive clean-energy technologies. However, their nonlinear dynamics and
coupling among variables pose substantial control challenges. To address these
challenges, this study investigates the controllability of PEMFCs and designs
an Internal Model Control tuned PI (IMC-PI) controller. A reduced-order PEMFC
model for hydrogen (H2) and oxygen (O2) gases was developed, assuming
steady-state water pressure dynamics The steady state water pressure dynamics
was maintained by the introduction of a variable that cancels out its dynamic.
Model controllability was assessed using the Popov-Belevitch-Hautus (PBH)
criterion and the controllability Gramian. Proportional-Integral (PI) and
Internal Model Control-based PI (IMC-PI) controllers were implemented for
reference tracking of hydrogen and oxygen partial pressures. For the hydrogen
channel, IMC-PI and PI systems have rise times of 0.005 seconds and 0.020
seconds, respectively, along with settling times of 0.005 seconds and 0.040
seconds, respectively. Additionally, the ISE error indices were 1.04 × 10⁻⁵ and 9.22 ×
10⁻⁵, respectively. Similarly, for the oxygen channel,
IMC-PI and PI controllers have a rise time of 0.002 seconds and 0.010 seconds,
respectively, with settling times of 0.010 seconds and 0.020 seconds,
respectively, with absent of overshoot. These results show that IMC-PI achieves
faster rise and settling times, eliminates overshoot, and reduces error indices
more effectively than traditional PI control. The findings showed that IMC-PI
tuning offers a more effective and robust method for ensuring the stable and
efficient operation of PEMFCs and it is therefore recommended not only for
practical PEMFC control applications but for future experimental validation and
integration with advanced control strategies.
Keywords: PEMFC; Nonlinear dynamics; Controllability analysis; PBH criterion; Reduced-order model; PID controller; IMC
https://doi.org/10.33922/j.ujet_v11i2_7
|
View: 21 | Download: 1
Published
Monday, July 14, 2025
Issue
Vol. 11 No. 2, December 2025
Article Section
GENERAL