ABSTRACT
This paper focused on the
mathematical model for optimizing the charge (recycled scrap)
and heel level in an iron remelting electric arc furnace. The charge (recycled
scrap)
and the heel were charge into the furnace in varying proportion with the
recycled scrap
from 90% - 30% step 5 as against the heel from 10% - 70% step 5. The heat
energy equation model required for melting of scrap
was developed and used. This energy efficient used in electric arc furnace(EAF)
operation require careful monitoring and skillful manipulation of different
parameters. A computer programme written in basic programming language to
optimize the charge/heel level in the electric arc furnace has also been
developed, using the recycled scrap as charged material. Time and
cost of electrical energy consumption were considered as the decision
variables. The results for optimizing the recycled scrap
and heel level charge in right proportion showed that charged scrap
and heel level of 60% - 40% was the optimum ratio for economical productivity
in terms of the tap to tap time, furnace eroding energy consumption and
electrode consumption.
Keywords: Recycled Scrap, Heel, Electric arc furnace,Optimization, Fortran, Remelting
|